小型(xing)恒溫恒濕箱(xiang)運(yun)行時出現故障異常怎(zen)么辦

        小型(xing)恒(heng)溫恒(heng)濕(shi)箱(xiang)(xiang)又稱(cheng)桌上(shang)型(xing)恒(heng)溫恒(heng)濕(shi)試(shi)驗箱(xiang)(xiang)或迷(mi)你型(xing)恒(heng)溫恒(heng)濕(shi)箱(xiang)(xiang),除了使(shi)用(yong)(yong)(yong)人(ren)員正確的(de)按操(cao)作流程(cheng)操(cao)作外,還(huan)應(ying)該要對結(jie)構有所(suo)了解(jie)。小型(xing)恒(heng)溫恒(heng)濕(shi)試(shi)驗箱(xiang)(xiang)的(de)結(jie)構是由(you)風(feng)循(xun)環(huan)系(xi)(xi)(xi)統(tong)(tong)(tong)(tong)、制(zhi)冷系(xi)(xi)(xi)統(tong)(tong)(tong)(tong)、加(jia)溫系(xi)(xi)(xi)統(tong)(tong)(tong)(tong)及控(kong)濕(shi)系(xi)(xi)(xi)統(tong)(tong)(tong)(tong)所(suo)組(zu)成的(de)。而(er)這些(xie)系(xi)(xi)(xi)統(tong)(tong)(tong)(tong)的(de)存在直(zhi)接(jie)與(yu)試(shi)驗箱(xiang)(xiang)價格的(de)高低有著密(mi)切(qie)的(de)關(guan)系(xi)(xi)(xi)。風(feng)循(xun)環(huan)系(xi)(xi)(xi)統(tong)(tong)(tong)(tong)一(yi)般采(cai)(cai)(cai)(cai)用(yong)(yong)(yong)的(de)是可調(diao)節(jie)送風(feng)方向(xiang)的(de)結(jie)構,加(jia)濕(shi)系(xi)(xi)(xi)統(tong)(tong)(tong)(tong)有采(cai)(cai)(cai)(cai)用(yong)(yong)(yong)鍋爐(lu)加(jia)濕(shi)的(de)和(he)表(biao)面蒸發兩(liang)種(zhong)。降溫、去濕(shi)系(xi)(xi)(xi)統(tong)(tong)(tong)(tong)采(cai)(cai)(cai)(cai)用(yong)(yong)(yong)的(de)是空(kong)調(diao)工況制(zhi)冷結(jie)構。加(jia)熱(re)(re)系(xi)(xi)(xi)統(tong)(tong)(tong)(tong)采(cai)(cai)(cai)(cai)用(yong)(yong)(yong)的(de)是電(dian)熱(re)(re)鰭片(pian)加(jia)熱(re)(re)和(he)電(dian)爐(lu)絲(si)直(zhi)接(jie)加(jia)熱(re)(re)二種(zhong)結(jie)構,溫濕(shi)度(du)測試(shi)方法(fa)(fa)采(cai)(cai)(cai)(cai)用(yong)(yong)(yong)干濕(shi)球測試(shi)方法(fa)(fa),也有用(yong)(yong)(yong)濕(shi)度(du)傳感器(qi)直(zhi)接(jie)測量方法(fa)(fa)。控(kong)制(zhi)和(he)顯示操(cao)作界面采(cai)(cai)(cai)(cai)用(yong)(yong)(yong)溫濕(shi)度(du)分(fen)開獨立和(he)溫濕(shi)度(du)組(zu)合控(kong)制(zhi)器(qi)等方式。

   KOWIN小型恒(heng)溫(wen)(wen)恒(heng)濕箱在做高(gao)溫(wen)(wen)試驗中,如果(guo)溫(wen)(wen)度變(bian)化達不到試驗溫(wen)(wen)度值時,可以(yi)檢查(cha)電(dian)(dian)器系統(tong),逐(zhu)漸一排除(chu)故障(zhang)。如溫(wen)(wen)度升(sheng)得(de)很慢,那就(jiu)要查(cha)看風(feng)循(xun)(xun)環(huan)(huan)系統(tong),看一下(xia)風(feng)循(xun)(xun)環(huan)(huan)的調(diao)節檔板是否開啟正(zheng)常,反之,就(jiu)檢查(cha)風(feng)循(xun)(xun)環(huan)(huan)的電(dian)(dian)機運轉是否正(zheng)常。如溫(wen)(wen)度過沖厲害那么就(jiu)需要整定(ding)PID的設置參數(shu)。如果(guo)溫(wen)(wen)度直接上升(sheng),過溫(wen)(wen)保護(hu),那么,控制器出故障(zhang),須更換控制儀表(biao)。

    低溫(wen)達(da)不到(dao)(dao)試(shi)驗(yan)的(de)(de)(de)指標,那(nei)就要(yao)觀(guan)察(cha)溫(wen)度的(de)(de)(de)變化,是溫(wen)度降的(de)(de)(de)很慢,還是溫(wen)度到(dao)(dao)一定值后(hou)(hou)溫(wen)度有回升(sheng)的(de)(de)(de)趨(qu)勢,前(qian)者就要(yao)檢查一下,做低溫(wen)試(shi)驗(yan)前(qian)是否(fou)將工作(zuo)室烘干,使(shi)(shi)工作(zuo)室保持干燥后(hou)(hou)再將試(shi)驗(yan)樣(yang)品(pin)放入工作(zuo)室內(nei)(nei)(nei)再做試(shi)驗(yan),工作(zuo)室內(nei)(nei)(nei)的(de)(de)(de)試(shi)驗(yan)樣(yang)品(pin)是否(fou)放置的(de)(de)(de)過多,使(shi)(shi)工作(zuo)室內(nei)(nei)(nei)的(de)(de)(de)風(feng)不能充分循環,在排除上述(shu)原因后(hou)(hou),就要(yao)考慮是否(fou)是制冷系統中(zhong)的(de)(de)(de)故(gu)障了(le),如果是這樣(yang)的(de)(de)(de)話那(nei)么就要(yao)請廠家(jia)專業人(ren)員進行檢修了(le)。

    在做濕(shi)(shi)(shi)(shi)(shi)熱(re)(re)試(shi)(shi)驗(yan)(yan)中(zhong),出現實(shi)際(ji)濕(shi)(shi)(shi)(shi)(shi)度會達到(dao)100%或(huo)者實(shi)際(ji)濕(shi)(shi)(shi)(shi)(shi)度與目標濕(shi)(shi)(shi)(shi)(shi)度相(xiang)差很(hen)大,數(shu)值低得很(hen)多,前(qian)者的(de)現象:可能(neng)是(shi)(shi)濕(shi)(shi)(shi)(shi)(shi)球(qiu)傳感器上(shang)的(de)紗(sha)布(bu)(bu)干燥引起,那(nei)(nei)就(jiu)(jiu)要(yao)檢查(cha)濕(shi)(shi)(shi)(shi)(shi)球(qiu)傳感器的(de)水(shui)(shui)槽中(zhong)是(shi)(shi)否缺水(shui)(shui),水(shui)(shui)槽中(zhong)的(de)水(shui)(shui)位(wei)(wei)是(shi)(shi)由(you)一(yi)(yi)水(shui)(shui)位(wei)(wei)控(kong)制(zhi)器自動控(kong)制(zhi)的(de),查(cha)水(shui)(shui)位(wei)(wei)控(kong)制(zhi)器供水(shui)(shui)系(xi)(xi)統(tong)是(shi)(shi)否供水(shui)(shui)正常(chang),水(shui)(shui)位(wei)(wei)控(kong)制(zhi)器工作(zuo)是(shi)(shi)否正常(chang)。另一(yi)(yi)種可能(neng)就(jiu)(jiu)是(shi)(shi)濕(shi)(shi)(shi)(shi)(shi)球(qiu)紗(sha)布(bu)(bu)因使(shi)用(yong)時間(jian)長,或(huo)供水(shui)(shui)水(shui)(shui)質(zhi)純凈度的(de)原(yuan)因,會使(shi)紗(sha)布(bu)(bu)變硬,使(shi)紗(sha)布(bu)(bu)無法(fa)吸(xi)收水(shui)(shui)份而干燥,只要(yao)更換或(huo)清洗紗(sha)布(bu)(bu)即可排(pai)除(chu)以上(shang)現象。后者的(de)現象主要(yao)是(shi)(shi)加濕(shi)(shi)(shi)(shi)(shi)系(xi)(xi)統(tong)不工作(zuo),查(cha)看加濕(shi)(shi)(shi)(shi)(shi)系(xi)(xi)統(tong)的(de)供水(shui)(shui)系(xi)(xi)統(tong),供水(shui)(shui)系(xi)(xi)統(tong)內是(shi)(shi)否有一(yi)(yi)定的(de)水(shui)(shui)量(liang),控(kong)制(zhi)加濕(shi)(shi)(shi)(shi)(shi)鍋(guo)爐水(shui)(shui)位(wei)(wei)的(de)水(shui)(shui)位(wei)(wei)控(kong)制(zhi)是(shi)(shi)否正常(chang),加濕(shi)(shi)(shi)(shi)(shi)鍋(guo)爐內的(de)水(shui)(shui)位(wei)(wei)是(shi)(shi)否正常(chang)。如以上(shang)一(yi)(yi)切都正常(chang),那(nei)(nei)就(jiu)(jiu)要(yao)檢查(cha)電器控(kong)制(zhi)系(xi)(xi)統(tong),這要(yao)請專業維(wei)修(xiu)人員進行(xing)檢修(xiu)。東(dong)莞市科文(wen)試(shi)(shi)驗(yan)(yan)設備有限(xian)公(gong)司專業維(wei)修(xiu)小型(xing)恒溫(wen)恒濕(shi)(shi)(shi)(shi)(shi)箱(xiang)(xiang),可程式恒溫(wen)恒濕(shi)(shi)(shi)(shi)(shi)試(shi)(shi)驗(yan)(yan)箱(xiang)(xiang),高(gao)低溫(wen)濕(shi)(shi)(shi)(shi)(shi)熱(re)(re)試(shi)(shi)驗(yan)(yan)箱(xiang)(xiang),交變濕(shi)(shi)(shi)(shi)(shi)熱(re)(re)試(shi)(shi)驗(yan)(yan)箱(xiang)(xiang),濕(shi)(shi)(shi)(shi)(shi)熱(re)(re)老化試(shi)(shi)驗(yan)(yan)箱(xiang)(xiang),溫(wen)濕(shi)(shi)(shi)(shi)(shi)度試(shi)(shi)驗(yan)(yan)箱(xiang)(xiang),高(gao)低溫(wen)試(shi)(shi)驗(yan)(yan)箱(xiang)(xiang),高(gao)低溫(wen)老化箱(xiang)(xiang),冷(leng)熱(re)(re)沖擊(ji)測試(shi)(shi)箱(xiang)(xiang),小型(xing)冷(leng)熱(re)(re)沖擊(ji)試(shi)(shi)驗(yan)(yan)箱(xiang)(xiang),大型(xing)冷(leng)熱(re)(re)沖擊(ji)試(shi)(shi)驗(yan)(yan)箱(xiang)(xiang),三箱(xiang)(xiang)式冷(leng)熱(re)(re)沖擊(ji)試(shi)(shi)驗(yan)(yan)箱(xiang)(xiang),高(gao)溫(wen)老化箱(xiang)(xiang)等。

Contact Us
  • 聯系手機:(微信同號)
  • 聯系QQ:1908114701
  • 聯系郵箱:
  • 聯系電話: 83819138
  • 聯系地址:東莞市常平鎮橋瀝馬屋新村二街53號

掃一(yi)掃  加關(guan)注

掃碼獲取報價方案

©2023 廣東科文試驗設備有限公司 版權所有  備案號:    GoogleSitemap

主營:高低溫測試箱,濕熱老化試驗箱,快速溫變箱,氣候模擬試驗箱,冷熱沖擊箱,溫度循環試驗箱

聯系電話:

掃一掃,微信咨詢